Description
  • Magnetic Starter
  • Type Full Voltage, Magnetic, Non-Combination, Non-Reversing
  • Current Rating 45 Ampere
  • Phase 3
  • Coil Voltage 110 VAC at 50 Hz, 115 to 120 VAC at 60 Hz
  • Size NEMA 2
  • Enclosure Type Open
  • Overloads 3-Phase 3-Leg Block Thermal Overload Relay
  • Construction Standard NEMA

Features / Benefits

  • Magnetic Motor Starters May be Used for Starting Full Voltage, Non-Reversing, Single Speed AC Motors Upto 1600 Horsepower, 600 Volts Maximum, Providing Protection to the Motor Against Running or Stalled Overloads
  • Their Compact Size and Ease of Wiring Make them Especially Suitable for Motor Control Centers, Custom Type Control Panels and Switchgear Equipment
  • Toolless Contactor Disassembly (Sizes 00-4) Allows Quick Access for Inspection and Maintenance
  • Just Release Two Retainers and Pull a Clip to Get at Magnet, Coil and Contacts
  • Saddle Clamp Terminals (Sizes 00-1) Accommodate Ring, Spade and Stripped Wire Leads and Carry Permanent Stamped-In Identification
  • Staggered Arrangement Makes Wiring Easier and Helps Prevent Shorting Between Phases
  • Current Carrying Components Contact Tips Are Weld Resistant Silver Cadmium Oxide (Fine Silver on Sizes 00 and 0 Only)
  • Contacts Are Installed in a Wedge Configuration for Positive Make with Minimum Bounce
  • Class 20 Overload Protection
  • Visual Trip Indicator with Manual Reset to Avoid Surprise Restarts
  • Reset Occurs on Arm Upstroke So a Tripped Condition Cant be Overridden by Holding the Arm Down
  • Manual Weld Check Provides a Convenient Test Against Welding of Overload Relay Contacts
  • Just Depress the Weld Check Operator to Trip the Relay, Run a Simple Continuity Test Across the Relay Contacts, then Depress the Manual Reset to Return the Starter to Service
  • Optional Isolated No Contact on the Overload Relay Provides Means of Direct Interface with Programmable Controller or Computer to Monitor Performance and Diagnose Faults
  • Dual Bimetals Anticipate Overloads, Responding to Rising Current and Temperature with Faster Tripping on Severe Overloads for Better Motor Protection
  • Trip Points Are Factory Calibrated for Accuracy
  • +/-10 Percent Trip Adjustment by Turning a Dial in the Overload Relay Face Allows Tuning the Protection to the Motor on the Spot

CR306D002 110/115 to 120 VAC at 50/60 Hz Coil, 45 A, 3-Phase, NEMA 2, Open, Full Voltage, Non-Combination, Non-Reversing, Magnetic Starter

$739.53 / EA
Availability: 16 EA
SKU
CR306D002
Manufacturer:
  General Electric
By placing an order you agree to Terms & Conditions
EA
More Information
Commodity Level DescripNEMA Non-Combination Starters
Brand NameSeries CR306
ManufacturerGeneral Electric
UPC783166358689
UNSPSC39121521
Commodity Code41350
SizeNEMA 2
Phase3
Overloads3-Phase 3-Leg Block Thermal Overload Relay
TypeFull Voltage, Magnetic, Non-Combination, Non-Reversing
Current Rating45 Ampere
Construction StandardNEMA
Coil Voltage110 VAC at 50 Hz, 115 to 120 VAC at 60 Hz
Enclosure TypeOpen